What’s Included
- 33XR-A
- Test leads with threaded alligator clips
- 9 V battery (installed)
- Magne-Grip™ Holster with magnetic hanging strap
- Temperature adapter
- Type K thermocouple probe
- Spare fuse
Specifications
FEATURE | 33XR-A |
DC Voltage | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
AC Voltage | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V |
DC Current | 400.0 µA, 4.000 mA, 40.00 mA, 300.0 mA, 10 A |
AC Current | 400.0 µA, 4.000 mA, 40.00 mA, 300.0 mA, 10 A |
Resistance | 400.0 O, 40.00 kO, 4.000 MO |
Continuity | • |
Diode | • |
VolTect™ Non-Contact Voltage Detection | – |
Capacitance | 4.000 µF, 40.00 µF, 400.0 µF, 4000 µF |
Frequency | 4.000 kHz, 40.00 kHz, 400.0 kHz, 1 MHz |
Temperature | 1832 °F (1000 °C) |
Duty cycle | – |
Logic test | – |
Inductance | – |
dBm | – |
Specifications | |
DC Voltage ranges | 400 mV, 4 V, 40 V, 400 V, 1000 V |
DC Voltage accuracy | All ranges: ± (0.7 % rdg + 1 dgt) |
DC Voltage resolution | 100 µV |
DC Voltage input impedance | 10 MO |
AC Voltage (45 Hz to 500 Hz) ranges | 400 mV, 4 V, 40 V, 400 V, 750 V |
AC Voltage (45 Hz to 500 Hz) accuracy | 4 V Range, 200 Hz to 500 Hz: ± (2.0 % rdg + 4 dgts)
All other ranges: ± (1.5 % rdg + 4 dgts) |
AC Voltage (45 Hz to 500 Hz) resolution | 100 µV |
AC Voltage (45 Hz to 500 Hz) input impedance | 10 MO |
DC Current ranges | 400 µA, 4 mA, 40 mA, 300 mA, 10 A |
DC Current accuracy | 400 µA to 300 mA ranges: ± (1.0 % rdg + 1 dgt)
10 A range: ± (2.0 % rdg + 3 dgts) |
DC Current resolution | 0.1 µA |
DC Current voltage burden | 400 µA range: 1 mV/µA, 4 mA range: 100 mV/1 mA, 40 mA range: 12 mV/1 mA
300 mA range: 4 mV/1 mA, 10 A range: 100 mV/1 A |
AC Current (45 Hz to 500 Hz) ranges | 400 µA, 4 mA, 40 mA, 300 mA, 10 A |
AC Current (45 Hz to 500 Hz) accuracy | 400 µA to 300 mA ranges: ± (1.5 % rdg + 4 dgts)
10 A range: ± (2.5 % rdg + 4 dgts) |
AC Current resolution | 0.1 µA |
AC Current voltage burden | See DC Current |
Resistance ranges | 400 O 40 kO 4 MO |
Resistance accuracy | 400 Oand 40 kO ranges: ± (1.0 % rdg + 4 dgts)
4 MO range: ± (1.2 % rdg + 4 dgts) |
Resistance resolution | 100 mO |