What’s Included
- 38XR-A
- Test leads with threaded alligator clips
- Temperature adaptor
- Type K thermocouple probe
- 9 V battery (installed)
- Magne-Grip™ Holster with magnetic hanging strap
- Spare fuse
Specifications
FEATURE | 38XR-A |
DC Voltage | 1.000 mV, 10.00 V, 100.0 V, 1000 V |
AC Voltage | 1.000 mV, 10.00 V, 100.0 V, 1000 V |
DC Current | 100.0 µA, 1.000 µA, 10.00 mA, 100.0 mA, 400.0 mA, 10.00 A |
AC Current | 100.0 µA, 1.000 µA, 10.00 mA, 100.0 mA, 400.0 mA, 10.00 A |
Resistance | 1000.0 O, 10.000 kO, 100.00 kO, 1000.0 kO, 10.00 MO , 40.00 MO |
Continuity | • |
Diode | • |
VolTect™ Non-Contact Voltage Detection | – |
Capacitance | 40.00 nF. 400.0 nF, 4.000 µF, 40.00 µF, 400.0 µF |
Frequency | 100.00 Hz, 1.0000 kHz, 10.000 kHz, 100.00 kHz, 1.0000 MHz, 10.000 MHz |
Temperature | 2372 °F (1300 °C) |
Duty cycle | 0.00 % → 90.0 % |
Logic test | – |
Inductance | – |
dBm | -13 dBm → + 50 dBm |
Specifications | |
DC Voltage ranges | 1000 mV, 10 V, 100 V, 1000 V |
DC Voltage accuracy | All ranges ± (0.25 % rdg + 5 dgt) |
DC Voltage resolution | 100 µV |
AC Voltage (45 Hz to 2 kHz) True-rms ranges | 1000 mV, 10 V, 100 V, 750 V |
AC Voltage (45 Hz to 2 kHz) True-rms accuracy | 750 V range: 45 to 1 kHz: ± (2.0 % rdg + 10 dgts)
All other ranges, 45 to 500 Hz: ± (1.2 % rdg + 10 dgts) All other ranges, 500 to 2 kHz: ± (2.0 % rdg + 10 dgts) |
AC coupled | True RMS specified from 5 % to 100 % of range |
AC + DC Voltage (45 Hz to 2 kHz) | 1000 mV, 10 V, 100 V, 750 V |
DC Current ranges | 100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A |
DC Current accuracy | 100 µA range: ± (0.5 % rdg + 10 dgt)
1000 uA to 400 mA ranges: ± (0.5 % rdg + 5 dgts) 10 A range: ± (1.5 % rdg + 10 dgt) |
DC Current resolution | 0.01 µA |
AC Current (True-rms) ( AC + DC) (45 Hz – 1 kHz) ranges | 100 µA, 1000 µA, 10 mA, 100 mA, 400 mA, 10 A |
AC Current (True-rms) ( AC + DC) (45 Hz – 1 kHz) accuracy | 100 µA to 100 mA ranges: ± (1.5 % rdg + 10 dgts)
400 mA range: ± (2.0 % rdg + 10 dgts) 10 A range: ± (2.5 % rdg + 10 dgts) |
AC Current (45 Hz to 1 kHz) True-rms resolution | 0.01 µA |
Resistance ranges | 1000 O 10 kO 100 kO 1000 kO 10 MO 40 MO |
Resistance accuracy | 1000 O to 1000 kO ranges: ± (0.5 % rdg + 8 dgts)