What’s Included
- ACD-20SW
- Test leads
- Battery (installed)
- Carrying case
Resources
Datasheet » |
Product Manual » |
Specifications
FEATURE | ACD-20SW | ACD-21SW | ACD-21SWC* | ACD-22SW | ACD-23SW | BEST ACCURACY |
TRMS | – | – | – | • | • | – |
AC Current | 40.00 A , 400.0 A | +/- (2.0 % rdg + 10 dgts) 50 Hz → 60 Hz |
||||
AC Voltage | 4.000 V, 40.00 V, 400.0 V, 600.0 V | +/- (1.2% rdg + 8 dgts) → 400 V Hz |
||||
DC Voltage | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 600.0 V | +/- (0.5% rdg + 2 dgts) | ||||
Resistance | 400.0 ?, 4.000 k?, 40.00 k?, 400.0 k?, 4.000 M?, 40.00 M? | +/- (1.0% rdg + 4 dgts) at 400 ? → 400 k? ranges | ||||
Capacitance | – | 4.000 µF, 40.00 µF, 400.0 µF, 4,000 µF |
– | 4.000 µF, 40.00 µF, 400.0 µF, 4,000 µF |
+/- (3.0 % rdg + 15 dgts) on 40 µF → 400 µF ranges |
|
Temperature | – | -30 °F → 400 °F | -35 °C → 400 °C | – | -30 °F →400 °F, (-35 °C → 400 °C) | +/- (1 % + 2 °F) -4 °F → 400 °F +/- (1 % + 1 °C) 0 °C → 200 °C |
Diode test | • | – | – | – | – | – |
VolTect™ non-contact voltage detection | 70 V → 600 VAC (50 Hz → 60 Hz) | – | ||||
Backlight | – | – | – | • | • | – |
Accommodates conductors | Up to 1.18″ (30 mm) in diameter |
Specifications | |
Display: | 3¾ digit liquid crystal display (LCD) with a maximumreading of 3999 |
Polarity: | Automatic, positive implied, negative polarityindication |
Overrange: | (OL) or (-OL) is displayed |
Zero: | Automatic |
Measurement rate: | 2 times per second, nominal |
Accuracy: | Stated accuracy at 74°F ±8°F, <75% relativehumidity. |
Jaw opening capability: | 30mm (1.18 in) conductor. |
Power: | 1.5 volt battery x2, R03/SIZE AAA. |
DC volts ranges: | 400mV, 4V, 40V, 400V, 600V |
Accuracy: | ±(0.5% rdg + 2 dgts) |
AC Volts (50hz – 500hz) ranges: | 4V, 40V, 400V, 600V |
Accuracy: | ±(1.2% rdg + 5 dgts) ±(1.5% rdg + 5 dgts) on 600V range |
AC Current (50hz – 60hz) ranges: | 40A , 400A |
Accuracy: | ±(2.0% rdg + 6 dgts) 50 ~ 60Hz |
Resistance ranges: | 400O, 4kO, 40kO, 400kO, 4MO, 40MO |
Accuracy: | ±(1.0% rdg + 4 dgts) on 400O to 400kO ranges |
Accuracy: | ±(1.5% rdg + 4 dgts) on 4MOrange |
Accuracy: | ±(3.0% rdg + 5 dgts) on 40MO range |
Continuity range: | 400O |
Diode test current: | 1.2mA (approximate) |
Accuracy: | ±(3.0% rdg + 3 dgts) |
Non-contact voltage indicator: | Sense voltage 70V to 600VAC (50Hz ~ 60Hz) beeper chirps and big bright red LED comes on, works when meter dial is on any ranges. |