Amprobe ACD-51NAV CAT IV 600 A TRMS Navigator Clamp Meter
Product Highlights
This versatile clamp-on power meter offers a full range of diagnostics, including those that HVAC technicians need most—volts, amps, resistance, capacitance, DC microamps, in-rush current and temperature.
A great clamp-on multimeter choice for troubleshooting or maintaining air conditioning or motor efficiency, measuring phase rotation, and identifying harmonics. Convenient joystick enables quick single-handed function selection.
- True-rms technology improves accuracy in noisy environments
- Measures AC/DC voltage to 1000 V, AC current to 600 A, plus resistance, frequency, capacitance, power factor, total harmonics distortion (THD) and individual harmonics from 1 to 25
- Measures temperature from -58 °F to 1832 °F (-50 °C to 1000 °C)
- Provides DC micro amps measurements to test flame sensors
- Includes inrush current measurement and phase rotation indication for 3-phase motors
- Non-contact voltage detection enhances safety
- Low pass filter enables measuring voltage and frequency on variable frequency drives
- Continuity beeper quickly identifies shorts and opens
- Large backlit digital display with analog bar graph presents the full picture
- Min, max and smart data hold
- Peak hold identifies spikes and transients
- In-jaw flashlight automatically lights when jaws open to illuminate dark panels and junction boxes
- Auto power off conserves battery life
- Maximum jaw opening accommodates large conductors up to 1.45″ (37 mm)
- Rubber overmold body absorbs shocks—drop proof to 4 feet (1.2 m)
- CAT IV-rated
What’s Included
- ACD-51NAV
- Test leads
- Batteries (installed)
- Carrying case
- Banana k-type thermocouple
Resources
Specifications
AC Current |
100.00 A, 600.0 A |
100.00 A, 1000.0 A |
+/- (1.5 % rdg + 5 LSD) |
DC Current |
_ |
_ |
100.00 A, 600.0 A |
_ |
100.00 A, 1000.0 A |
+/- (1.5 % rdg + 5 LSD) |
AC Voltage |
100.00 V, 1000 V |
+/- (1.0 % rdg + 5 LSD) |
DC Voltage |
100.00 V, 1000 V |
+/- (0.7 % rdg + 2 LSD) |
Resistance |
1.0000 KO, 10.00 KO, 100.00 KO |
+/- (1.0 % rdg + 3 LSD) |
Frequency |
20.0 Hz to 10 KHz |
+/- (0.5 % rdg +3 LSD) |
Capacitance |
400.0 µF, 4.000 mF |
+/- (1.9 % rdg + 8 LSD) |
DCµA |
_ |
1000.0 µA |
_ |
_ |
_ |
+/- (1.7 % rdg + 2 LSD) |
Temperature |
_ |
-50 °F → 1832 °F (-50 ºC → 1000 ºC) |
_ |
_ |
-50 °F → 1832 °F (-50 ºC → 1000 ºC) |
+/- (1 % rdg + 0.8 ºC) |
THD (Total harmonics distortion) |
0.1% → 100.0% |
+/- (3.0 % rdg + 10 LSD) |
Individual harmonics |
1 → 25 |
_ |
Power |
10 kW → 600 kW |
10 kW → 1000 kW |
+/- (2.5 % rdg + 5 LSD) |
Power factor |
-1.00 → 1.00 |
+/- 3 degrees |
Accommodates conductors |
Up to 1.45″ (37 mm) in diameter |
Up to 1.60″ (40 mm) in diameter |
|